Key Features Of Dual Fuel Burner:
Technical Data Of Dual Fuel Burner:
MODEL | RLS 28 | RLS 38 | RLS 50 | RLS 70 | RLS 100 | RLS 130 | ||
Operation | Two stage | |||||||
Modulating ratio at max. ouput | 2:1 | |||||||
Servomotor | type | LKS 210 - 08 | LKS 210 -10 | |||||
run time | s | 5 | ||||||
Heat output | kW | 100/163-325 | 116/232-442 | 145/290-581 | 232/465-814 | 349/698-1163 | 465/930-1395 | |
Mcal/h | 86/140-303 | 100/200-380 | 125/249-500 | 200/400-700 | 300/600-1000 | 400/800-1200 | ||
FUEL/AIR DATA | ||||||||
Working temperature | oC min/max | 0/40 | ||||||
Light oil | Net calorific value | kWh/kg | 11,8 | |||||
Viscosity at 20oC | mm2/s ( cSt) | 4-6 | ||||||
Delivery | kg/h | 8/14-28 | 10/20-37 | 12/25-49 | 20/39-69 | 30/59-99 | 39/79-118 | |
Max temperature | oC | 60 | ||||||
Pump | type | AL 65B | AJ 6CC | |||||
delivery | kg/h | 63 (at 15 bar) | 134 (at 20 bar) | |||||
Atomised pressure | bar | 12 | ||||||
G20 | Net calorific value | kWh/Nm3 | 10 | |||||
Density | kg/Nm3 | 0,71 | ||||||
Delivery | Nm3/h | 10/16-32,5 | 12/23-44 | 14,5/29-58 | 23/46,5-81 | 35/70-116 | 46,5/93-139,5 | |
G25 | Net calorific value | kWh/Nm3 | 8,6 | |||||
Density | kg/Nm3 | 0,78 | ||||||
Delivery | Nm3/h | 12/19-38 | 13/27-51 | 17/33-68 | 27/54-95 | 41/81-135 | 54/108-162 | |
LPG | Net calorific value | kWh/Nm3 | 25,8 | |||||
Density | kg/Nm3 | 2,02 | ||||||
Delivery | Nm3/h | 4/6-13 | 4/9-17 | 6/11-23 | 9/18-32 | 14/27-45 | 18/36-54 | |
Fan | type | Centrifugal - with reverse curve blades | ||||||
ELECTRICAL DATA | ||||||||
Air temperature | max oC | 60 | ||||||
Electrical supply | Ph / Hz / V | 1/50/230 (+10%) | 3N/50/230-400 (+10%) | |||||
Auxiliary electrical supply | Ph / Hz / V | 1/50/230 (+10%) | ||||||
Control box | type | LFL 1.333 | ||||||
Total electrical power | kW | 0,53 | 0,76 | 0,91 | 1,8 | 2,2 | 3 | |
Auxiliary electrical power | kW | 0,19 | 0,25 | 0,17 | 0,33 | 0,33 | 0,43 | |
Protection level | IP | 44 | ||||||
Fan electrical motor power | kW | 0,25 | 0,42 | 0,65 | 1,1 | 1,5 | 2,2 | |
Rated fan motor current | A | 2,1 | 2,9 | 3 -1,7 | 4,8 - 2,8 | 5,9 - 3,4 | 8,8 - 5,1 | |
Fan motor protection level | IP | 44 | 55 | 54 | ||||
Pump electric motor power | kW | 0,09 | 0,37 | |||||
Rated pump motor current | A | 0,8 | 2,4 | |||||
Pump motor start current | A | - | - | - | - | - | - | |
Pump motor protection level | IP | 44 | ||||||
Ignition transformer | V1- V2 | 230 V - 2 x 5 kV | ||||||
I1 - I2 | 1,9 A - 30 mA | |||||||
Working | Intermittent (at least one stop every 24h) | |||||||
EMISSIONS | ||||||||
Sound pressure | dBA | 68 | 70 | 72 | 74 | 77,5 | 80 | |
Sound power | W | - | - | - | - | - | - | |
Light oil | CO emissions | mg/kWh | < 20 | |||||
Grade of smoke indicator | No Bacharach | < 1 | ||||||
CxHy emissions | mg/kWh | < 10 | ||||||
NOx emissions | mg/kWh | < 190 | ||||||
G20 | CO emissions | mg/kWh | < 15 | |||||
NOx emissions | mg/kWh | < 80 | ||||||
APPROVAL | ||||||||
Directive | 90/396 - 89/336 - 73/23 - 92/42 EEC | |||||||
Conforming to | EN 267 - EN 676 | |||||||
Certifications | CE 0063 AR 4637 | CE 0063 AS 4863 - DIN 5G 835/97 M |