Owing to our vast infrastructure facilities, we are able to supply high quality Dual Fuel Burner. These burners are mostly used in diathermic oil boilers, steam generators and hot water boilers. Our vendors make use of best-in-class materials and components to manufacture these burners. The burners we offer are widely appreciated by our customers for their long lasting nature and excellent performance. The Dual Fuel Burner is available in various sizes and specifications to meet the requirements of our valued clients.

Key Features Of Dual Fuel Burner:

  • High quality
  • Excellent performance
  • Optimal combustion
  • Available in various sizes
  • Long lasting nature

 Technical Data Of Dual Fuel Burner:

MODEL
RLS 28
RLS 38
RLS 50
RLS 70
RLS 100
RLS 130
Operation Two stage
Modulating ratio at max. ouput
2:1
Servomotor
type

LKS 210 - 08
LKS 210 -10
run time
s
5
Heat output
kW
100/163-325
116/232-442
145/290-581
232/465-814
349/698-1163
465/930-1395
Mcal/h
86/140-303
100/200-380
125/249-500
200/400-700
300/600-1000
400/800-1200
FUEL/AIR DATA
Working temperature
oC min/max
0/40


Light oil
Net calorific value
kWh/kg
11,8
Viscosity at 20oC
mm2/s ( cSt)
4-6
Delivery
kg/h
8/14-28
10/20-37
12/25-49
20/39-69
30/59-99
39/79-118
Max temperature
oC
60
Pump
type

AL 65B
AJ 6CC
delivery
kg/h
63 (at 15 bar)
134 (at 20 bar)
Atomised pressure
bar
12

G20
Net calorific value
kWh/Nm3
10
Density
kg/Nm3
0,71
Delivery
Nm3/h
10/16-32,5
12/23-44
14,5/29-58
23/46,5-81
35/70-116
46,5/93-139,5

G25
Net calorific value
kWh/Nm3
8,6
Density
kg/Nm3
0,78
Delivery
Nm3/h
12/19-38
13/27-51
17/33-68
27/54-95
41/81-135
54/108-162

LPG
Net calorific value
kWh/Nm3
25,8
Density
kg/Nm3
2,02
Delivery
Nm3/h
4/6-13
4/9-17
6/11-23
9/18-32
14/27-45
18/36-54
Fan
type
Centrifugal - with reverse curve blades
ELECTRICAL DATA
Air temperature
max oC
60
Electrical supply
Ph / Hz / V
1/50/230 (+10%)
3N/50/230-400 (+10%)
Auxiliary electrical supply
Ph / Hz / V
1/50/230 (+10%)
Control box
type
LFL 1.333
Total electrical power
kW
0,53
0,76
0,91
1,8
2,2
3
Auxiliary electrical power
kW
0,19
0,25
0,17
0,33
0,33
0,43
Protection level
IP
44
Fan electrical motor power
kW
0,25
0,42
0,65
1,1
1,5
2,2
Rated fan motor current
A
2,1
2,9
3 -1,7
4,8 - 2,8
5,9 - 3,4
8,8 - 5,1
Fan motor protection level
IP
44
55
54
Pump electric motor power
kW
0,09 0,37
Rated pump motor current
A
0,8
2,4
Pump motor start current
A
-
-
-
-
-
-
Pump motor protection level
IP
44
Ignition transformer
V1- V2
230 V - 2 x 5 kV
I1 - I2
1,9 A - 30 mA
Working

Intermittent (at least one stop every 24h)
EMISSIONS
Sound pressure
dBA
68
70
72
74
77,5
80
Sound power
W
-
-
-
-
-
-


Light oil
CO emissions
mg/kWh
< 20
Grade of smoke indicator
No Bacharach
< 1
CxHy emissions
mg/kWh
< 10
NOx emissions
mg/kWh
< 190
G20
CO emissions
mg/kWh
< 15
NOx emissions
mg/kWh
< 80
APPROVAL
Directive
90/396 - 89/336 - 73/23 - 92/42 EEC
Conforming to
EN 267 - EN 676
Certifications
CE 0063 AR 4637
CE 0063 AS 4863 - DIN 5G 835/97 M
क्रय आवश्यकता विवरण दर्ज करें
ईमेल आईडी
मोबाइल नंबर


Back to top