With our expertise in this domain, we are able to offer superior quality One Stage Light Oil Burners. These products are widely used in factories and residences for high pressure work and combustion. Our vendors manufacture these products at their well-equipped infrastructure facility. The range is made using superior quality components obtained from the authorized industries. We are able to offer these One Stage Light Oil Burners in various models and specifications to our esteemed clients.
Technical Data Of One Stage Light Oil Burners:
MODEL | RC2-26R | RC2-38R | RC2-46R | RC2.1-46R | ||
Burner operation mode | One stage | |||||
Modulation ratio at max. output | -- | |||||
Servomotor | run time | type | -- | |||
s | -- | |||||
Heat output | kW | 17 - 26 | 24 - 38 | 33 - 46 | 33 - 46 | |
Mcal/h | 14,6 - 22,4 | 20,6- 32,7 | 28,4 - 39,6 | 28,4 - 39,6 | ||
kg/h | 1,4 - 2,2 | 2,0- 3,2 | 2,8 - 3,9 | 2,8 - 3,9 | ||
Working temperature | deg C min./max. | 0/40 | ||||
FUEL / AIR DATA | ||||||
Net calorific value | kWh/kg | 11,8 | ||||
kcal/kg | 10200 | |||||
Viscosity | mm2/s (cSt) | 4 - 6 (at 20 deg C) | ||||
Pump | Delivery | type | R.B.L. | |||
kg/h | 30 (at 12 bar) | |||||
Atomised pressure | bar | 7 - 15 | ||||
Fuel temperature | max. deg C | 50 | ||||
Fuel pre-heater | YES | |||||
Fan | type | centrifugal with forward curve blades | ||||
Air temperature | max. deg C | 60 | ||||
ELECTRICAL DATA | ||||||
Electrical supply | Ph/Hz/V | 1/50/230+10% | ||||
Auxiliary electrical supply | Ph/Hz/V | -- | ||||
Control box | type | R.B.L. 531 SE | ||||
Total electrical power | kW | 0,150 | ||||
Auxiliary electrical power | kW | -- | ||||
Heaters electrical power | kW | 0,025 | ||||
Protection level | IP | 20 | ||||
Pump motor electrical power | kW | -- | ||||
Rated pump motor current | A | -- | ||||
Pump motor start up current | A | -- | ||||
Pump motor protection level | IP | -- | ||||
Fan motor electrical power | kW | 0,09 | ||||
Rated fan motor current | A | 0,75 | ||||
Fan motor start up current | A | 3 | ||||
Fan motor protection level | IP | 20 | ||||
Ignition transformer | type | Incorporated in the control box | ||||
V1 - V2 | 8 kV | |||||
I1 - I2 | 16 mA | |||||
Operation | Intermittent (at least one stop every 24 h) | |||||
APPROVAL EMISSIONS | ||||||
Sound pressure | dB (A) | 62,5 (with buffle plate), 57,5 (without buffle plate) | ||||
Sound power | W | -- | ||||
CO emission | mg/kWh | 8 | 2 | 8 | 1 | |
Grade of smoke indicator | N deg Bacharach | <1 | ||||
CxHy emission | mg/kWh | <10 (after the first 20s) | ||||
NOx emission | mg/kWh | 195 | 168 | 142 | 175 | |
Directive | 89/336/EEC, 73/23/EEC, 98/37/EEC, 92/42/EEC | |||||
Conforming to | EN 267 | |||||
Certification | CE 0036 0352/04 | in progress |
Reference conditions:
Product Specification
Burner:
Completely automatic monobloc light oil burners, with one stage operation made up of:
Combustion head made up of:
Geared pump for fuel supply, fitted with:
Fuel pre-heater.
Approval to:
EN 267.
Conforming to:
89/336/ EEC (electromagnetic compatibility)
73/23/EEC (low voltage)
98/37/EEC (machinery)
92/42/EEC (efficiency).
Standard Equipment: